7 Common Causes & How To Fix Pellet Stoves Shutting Off

  1. Dirty Pellet Stove Unit. Surprisingly, one of the most common issues is just that your stove is dirty. ...
  2. Faulty Stove Wiring. Your pellet stove does rely on electricity to help light the flames and power the fans, which circulate the heat around your home.
  3. Combustion Air Damper Needs Adjustment. ...
  4. Combustion Blower Spinning Too Slow. ...

More items...

A pellet stove that keeps shutting off is a sign that the stove requires cleaning, as either the fuel or the air is being blocked from getting the fire. The combustion chamber and hopper should be cleaned thoroughly. A pellet stove shutting off may also signal that a part is worn and needs replacing.Apr 26, 2021

Full Answer

How to reset a pellet stove?

Your Ravelli Pellet Stove will display the ‘No Pellet’ message for the following reasons:

  • There is no wood pellet into the hopper
  • The gear motor doesn’t function to load the wood pellets
  • No pellet loading

Why does my wood pellet stove keep going out?

  • using wood that is too wet.
  • not providing enough oxygen to the fire through misunderstanding how to use the air vents on the stove correctly.
  • Having a fire when the flue is dirty or the damper is too far closed.

Can I leave a pellet stove unattended overnight?

Is it safe to run a pellet stove overnight? American Energy Systems pellet stoves and fireplaces are designed to provide safe, consistent heat with minimal work. That means that you can start your stove and safely leave it unattended overnight, while you run for groceries, or meet friends for dinner.

What happens if my pellet stove loses power?

What happens when the power goes Out?

  • Waffleman. Have used wood stoves all my life but in my new home will be installing a pellet stove - most likely the Quadra fire Vermont AE (various reasons including ...
  • Peterfield. ...
  • johneh
  • BigJohnfromCT. ...
  • womaus. ...
  • MadMax31. ...
  • mralias. ...
  • Tonyray. ...
  • UpStateNY. ...
  • DneprDave. ...

More items...

Why does my pellet stove shut off on its own?

My Stove Keeps Shutting Down You may have noticed the common causes for most pellet stove problems by now – a dirty unit, and poor air adjustment which won't provide enough heat to trip the sensors. Also, your pellets might not being feeding into the auger correctly, due to a worn down or broken part.

Why does my pellet stove not stay lit?

0:191:50Why won't my fire stay lit in my Pellet Stove - YouTubeYouTubeStart of suggested clipEnd of suggested clipThis is caused by the pellet stove being dirty. And getting a collection of ash that builds up fromMoreThis is caused by the pellet stove being dirty. And getting a collection of ash that builds up from behind the fire brick. And into the combustion blower housing and back up into the chimney.

What does the low limit switch do on a pellet stove?

The "LOW LIMIT SWITCH" is the white ceramic disk by the exhaust fan. It is timed by the computer that if after 30 minutes, the stove exhaust fan will simply turn off and the stove will shut down if that switch does not feel the exhaust is above 120 degrees.

How long can you continuously run a pellet stove?

Settings on the control unit of a pellet stoves can typically be adjusted for burning times and required room temperatures, and so how long can pellet stoves burn for? Many models of pellet stove allow for 24 hours continuous burning each and every day as long as the hopper has a sufficient supply of pellets.

How do I know if my pellet stove auger is bad?

1:473:39How to know if your auger motor is bad - YouTubeYouTubeStart of suggested clipEnd of suggested clipYou can feel the auger motor is really hot. And that's a sign that it needs to be replaced that it'sMoreYou can feel the auger motor is really hot. And that's a sign that it needs to be replaced that it's gone bad.

How do you unclog a pellet stove?

0:081:37How to Fix A Pellet Stove Auger Jam - YouTubeYouTubeStart of suggested clipEnd of suggested clipIf you have access to the exterior auger housing you can try gently tapping the tube with the smallMoreIf you have access to the exterior auger housing you can try gently tapping the tube with the small rubber mallet to dislodge the blockage.

How do I know if my fan limit switch is bad?

One of the most common issues that happens when a high limit switch goes bad is that it fails to signal the blower fan to turn off. If your fan keeps running continuously (and you've checked that your thermostat is set to AUTO rather than ON), that could be a sign of a bad high limit switch.

How do I test a limit switch?

0:041:19Checking a limit switch using your voltmeter - YouTubeYouTubeStart of suggested clipEnd of suggested clipAs you can see Chris is going right there should be reading zero. Across the limit if it's notMoreAs you can see Chris is going right there should be reading zero. Across the limit if it's not tripped. Which should be reading zero terrific Chris.

How do you bypass a fan limit switch?

2:244:00How To Test and Bypass The Upper Limit Switch On Your FurnaceYouTubeStart of suggested clipEnd of suggested clipJust make sure your furnace is totally shut off you're just going to pull the wire straight offMoreJust make sure your furnace is totally shut off you're just going to pull the wire straight off depending on where your upper limit switch is in your furnace.

Can you leave pellet stove on overnight?

American Energy Systems pellet stoves and fireplaces are designed to provide safe, consistent heat with minimal work. That means that you can start your stove and safely leave it unattended overnight, while you run for groceries, or meet friends for dinner.

Is it OK to run a pellet stove 24 7?

Pellet stoves are designed for 24/7 operation. Just make sure you keep up with routine cleaning and maintenance as suggested by the manufacturer.

Can I open pellet stove while running?

Pellet stoves still use a real fire inside the combustion chamber to produce heat and so can pellet stoves be left unattended even through the whole heating process can be automated? In the majority of circumstances it can be fine to leave a pellet stove operating unattended.

Why does my stove shut off?

When the stove shuts off, the most common cause is that the unit is dirty or that there isn’t enough heat to trip the sensors.

What happens if you don't have an outside air supply?

If you do not have an outside air supply coming into your stove, it will draw air through the grilles on the side of your stove or the fireplace cover. If the air inlet is inhibited, the flame will create excess smoke even if your damper is all the way open.

What happens if your combustion blower is too slow?

Decreased airflow in the firebox will keep the air switch from sensing the correct level of vacuum. In this case, you will need to remove the combustion blower from the stove and perform a bench test.

How far away from the firebox should a burn pot be?

You need to check and see if your burn pot fits appropriately over the combustion air tube. Your burn pot needs to be mounted about 1/8” away from the wall of the firebox. If this isn’t correctly positioned, the air will not move through enough for your stove to operate the correct way.

What is the purpose of a combustion air damper?

The job of your combustion air damper is to limit the air that’s available to the fire. This allows you to adjust the air to fuel ration to burn your pellets at a desirable rate.

Can a stove have obstructions?

There cannot be any obstructions in the combustion air tube if the stove receives enough combustion air to operate correctly. If you have an older model and uses a coupling to join the damper blade and control rod, you may be misusing it, and it may have come loose.

What happens if the stove is over 200 degrees?

If the stove reaches over 200 or 250 degrees at the high limit switch. (because of a room air blower failure ) the switch will open and not allow power to flow to auger, Combstion bower or control board. Depending on stove. <example form a Breckwell owners manual>. STOVE SHUTS OFF AND THE # 3 LIGHT FLASHES:

What does a low limit switch on a stove do?

Most new stoves will flash a Feed light or heat level light and your manual will tell you what the problem is. Low limit switch is a temperature switch mounted to the stove. When stove is at its lowest operation temperature limit it will stop power to the blower (s) Shutting down the stove. When you turn the stove off the auger shuts off but ...

How long does it take for a combustion blower to work on a stove?

When you start you stove the Control board gives power to the Combustion blower for 15 minutes. then stops giving power to the blower. If the low limit reaches 120 or 140 degrees it will close (allowing power to flow threw it) and allow power to keep going to the combustion blower.

Why is it called a proof of fire switch?

If the stove reaches over 200 or 250 degrees at the high limit switch. (because of a room air blower failure) the switch will open and not allow power to flow to auger, Combstion bower or control board.

Why is my stove not closing?

Pressure Switch (Vacuum) . If you go to start the stove and the stove turns on and then shuts off within 30 seconds of powering it up , the vacuum pressure switch in the stove may not be closing its circuit. Most of the time, this has to do with a clogged hose, blocked vent, or dirty stove.

What causes a stove to blow out?

Windward venting connections. If your stove's venting is a straight shot out of your house, a gust of wind can sometimes create a "puff" in the stove, blowing the fire out. The Burnpot Is Full Of Partially Burned Pellets. The power was cut to the stove while it was running.

What happens if the exhaust blower fails?

If the exhaust blower fails (stops spinning), the stove will display a vacuum switch error. Always make sure the exhaust blower is spinning. Many stoves have a hopper lid switch in-line with the feed or the pressure switch, make sure the hopper lid is closed when troubleshooting.

Why is my burnpot empty?

The Burnpot Is Empty After Shutdown. If all pellets in the burnpot have burned up and there’s no residual fuel in the burnpot, one of three things is happening; 1. The feed motor is slowing down as the stove heats up, 2. The power to the feed motor is being interrupted, 3.

How to set damper on stove?

Luckily, when the stove is running, setting a damper is easy. When your stove has a high flame, close the damper fully, if you see an orange lazy flame, open the damper until the fire is bright and there is subtle movement on the burnpot of the smallest pellets. This is the correct setting. Burnpot.

What happens if a stove capacitor fails?

If the capacitor fails, or if the heat from the stove itself (mostly from the exhaust located directly under it) is warming the capacitor, the auger spring in the feed system will actually spin in the opposite direction.

What to do if you can't spin the blower wheel?

IF you cannot freely spin the blower wheel, replace the blower. If you left your stove plugged in during the offseason, or if it has been plugged in since the last time you used it, and you had a power surge, these switches can sometimes roll out and need to be reset. Error codes for this are usually #4 or #4 and #5.

Why does my pellet stove shut off?

The main reasons why a pellet stove is shutting off can include: A blocked air supply. If the burn pot inside the combustion chamber is full of ash and leftover unburnt pellets then this may be blocking the airflow to the fire through the holes in the burn pot. A blocked fuel supply.

Why is my pellet stove not feeding pellets?

A pellet stove that’s not feeding pellets can be a sign that the hopper needs filling up with pellets, the auger is jammed , the auger motor has failed , or the air inlet is blocked. Clean the stove thoroughly and if the stove still isn’t feeding pellets then professional help be required.

Why does my pellet stove keep jamming?

A pellet stove auger that keeps jamming can be caused by using the wrong size of pellets, too much pellet dust within the hopper and auger or a problem with the motor auger. Cleaning out the hopper regularly can help prevent a pellet stove auger from jamming.

How to keep auger from jamming on pellet stove?

To help prevent a pellet stove auger from jamming: Clean out the hopper and auger at regular intervals in line with what’s stated by the manufacturer’s guidelines. We’re required to vacuum our hopper at least every week to keep the dust to a minimum. Use high quality pellets that won’t break up easily.

Why does my pellet stove burn black?

A burning black pellet stove can be a result of: The air inlet to the whole stove blocked.

How does the ignition work on a pellet stove?

The ignition system (right hole under the burn pot of our pellet stove) should be clear of ash and pellets to work properly. The initial ignition of the pellets is commonly carried out by hot air that is sucked through the fume extractor and around the ignition in the combustion chamber.

Why isn't my pellet stove getting enough fuel?

Reasons why a pellet stove isn’t receiving enough fuel in the form of pellets can include: The auger and/or chute is blocked. There aren’t enough pellets in the hopper. The fuel isn’t being delivered at a fast enough rate.