GOD-POD Method For The Estimation Of Blood Glucose
- Reduction Methods:
- Aromatic amine condensation methods:
- Enzymatic Methods:
- Electrochemical methods: Being more specific, easier, and more accurate, enzymatic methods are preferred these days. Among them, the GOD-POD method is the most common method of glucose estimation.
What is the god POD method for glucose estimation?
What is God Pod method? Estimation of blood glucose. Glucose Oxidase for blood glucose estimation PRINCIPLE OF THE METHOD Glucose oxidase (GOD) catalyzes the oxidation of glucose to gluconic acid. The formed hydrogen peroxide (H2O2), is detected by a chromogenic oxygen acceptor, phenol- aminophenazone in the presence of peroxidase (POD).
What is a God Pod used for?
The formed hydrogen peroxide (H2O2), is detected by a chromogenic oxygen acceptor, phenol- aminophenazone in the presence of peroxidase (POD). Click to see full answer. People also ask, what is a god pod? Description: Simple colorimetric method for the determination of D-Glucose.
How do you detect hydrogen peroxide in God Pod?
The formed hydrogen peroxide (H2O2), is detected by a chromogenic oxygen acceptor, phenol- aminophenazone in the presence of peroxidase (POD). Click to see full answer. People also ask, what is a god pod?
What are the different methods of God PAP?
Other methods include the copper reduction method (modified Folin Wu), the o-toluidine method, glucose oxidase assay, and the glucose oxidase and peroxidase (GOD-POD) method. The hexokinase/G6PD method is described here as it is used most widely. Hereof, what is God PAP method? Method.
What does God-Pod mean?
glucose oxidase-peroxidaseGOD-POD (>> Co-occurring Abbreviation) Long Form: glucose oxidase-peroxidase.
What is God method?
A "God Method" is a method that does way too many processes in the system and has grown beyond all logic to become The Method That Does Everything. Lisp/Scheme Objects, implemented as closures, might qualify as a GodMethod.
Which enzymes are used in God-Pod method?
GOD-POD reagent enzymes. Freeze-dried powder of glucose oxidase (GOD; >12,000 U), peroxidase (POD; >650 U) and 4-aminoantipyrine (80 mg).
What is the full form of pod in God-Pod method?
Description: Simple colorimetric method for the determination of D-Glucose. Based on the combined action of Glucose oxidase (GOD) and Peroxidase (POD).
Is God Pod method accurate?
GOD-POD method was found linear (up to 500 mg/dl), with good precision (CV=0.7% to 1.4%) and accuracy (Average deviation= −0.97%). This method is simple, rapid, economical and sensitive, and can be adopted to a routine colorimeter.
How does God Pod method measure blood sugar?
4:2220:01Estimation of Plasma Glucose by GOD POD method - YouTubeYouTubeStart of suggested clipEnd of suggested clipAnd the hydrogen peroxide is catalyzed by the oxidase enzyme to the stool and niceness and oxygenMoreAnd the hydrogen peroxide is catalyzed by the oxidase enzyme to the stool and niceness and oxygen this four amino anti pyrin which is a oxygen acceptor will accept this nice and oxygen. And in the
What is God and POD method in biochemistry?
Glucose oxidase (GOD) - peroxidase (POD) is one of the highly sensitive method for estimation of glucose in the blood. Here simply glucose is oxidised to produce hydrogen peroxide which is utilized for oxidation and coupling of 4-aminoantipyrine and phenol to produce a colored product.
What is a normal HbA1c for type 2 diabetes?
The target HbA1c value for people with type 2 diabetes is 6.5% or 48 mmol/mol. If you get an HbA1c result at this level or below, you're on the right track with your diabetes control. If your HbA1c result is above this target, there is room for some improvement.
When should HbA1c levels be tested?
The test for HbA1c is used to diagnose and monitor diabetes. For people who have diabetes, the test is used to indicate how well the diabetes has been controlled over the last few months. People with diabetes are advised to have this test every 3 to 6 months, or more frequently if it is not under control.
Which method is best for glucose estimation?
Glucose is measured by various enzymatic methods. The hexokinase/glucose-6-phosphate dehydrogenase (G6PD) method developed by the American Association for Clinical Chemistry has been accepted as the reference method for glucose determination.
What is the full form of hba1c?
Glycated hemoglobinHemoglobin A1C / Full name
What is POD medical term?
POD or points of dispensing, are community locations in which state and local agencies dispense MCMs to the public during a public health emergency. To aid in rapidly dispensing MCMs, the local public health department will plan on using two types of PODs, open and closed.