by Bette Heathcote IV Published 3 years ago Updated 3 years ago

A pump saver device, of which there are several device types using different methods, is designed to protect the pump from damage if well flow rate is poor, by preventing the pump from running from then on (thus being damaged) by recycling water through a tailpiece as pump runs - until the well recovers.

Full Answer

What is a pump Saver used for?

PumpSavers are designed to protect single-phase pumps from dry-well, dead-head, rapid-cycling, jammed impeller, and over/undervoltage conditions. Typical applications include residential waterwells, commercial waterwells, irrigation wells, and golf course and other sprinkler systems.

Should I override the pump saver on my well?

If the well is really running dry you don't want to override the pump saver. There should be some kind of code or flash that tells you if and why the pump saver has shut off the pump. If it is giving a dry well code, it is sensing low amps and shutting the pump off.

What type of pumps does the pumpsaver® plus protect?

The Model 235P Single-phase PumpSaver® Plus is a pump monitor designed to protect singlephase pumps from dry-well, dead-head, rapid-cycle, jammed impeller, and over/under voltage conditions. The PumpSaver® Plus Model 235P protects 5 to 15 HP, 230VAC pumps.

What are the advantages of well pumps?

Additionally, well pumps are easy to maintain, and due to their run cycles shut on and off automatically to save you from high electricity bills. There are two types of wells depending on the well depth and the water table at your location. Shallow well pumps are non-submersible pumps that are placed outside the well.

What does a pump saver do?

1:153:19The Importance of a PumpSaver - YouTubeYouTubeStart of suggested clipEnd of suggested clipIt's monitoring that and it will shut the pump off if the voltage or amperage fluctuates by fifteenMoreIt's monitoring that and it will shut the pump off if the voltage or amperage fluctuates by fifteen percent from when we calibrated it if the pump runs out of water.

What is a pump saver on a well pump?

Details. The Model 233-P single-phase Pump Saver Plus is a pump monitor designed to protect single-phase pumps from dry-well, dead-head, jammed impeller, rapid cycle and overvoltage and undervoltage conditions.

How much is a pump saver?

Compare with similar itemsThis item PumpSaver Plus 233P-1.5-ENCL SymCom Low Yield Water Well Pump Protection MADE IN USAControl Box, 1 1/2HP, 230V, 1PhasePrice$26999$17150Sold ByVertikal SupplyIrrigation-MartBrand NameSymcomFranklinItem Weight0.01 ounces6.04 lbs5 more rows

How do I reset my pump saver?

The PumpSaver®Plus can also be calibrated while the pump is running. Turn the RESTART DELAY/ CALIBRATION knob to CAL. while pumping. Wait for the pump to turn off (approximately 10 seconds), then adjust the RESTART DELAY/ CALIBRATION knob to the desired setting.

How do you know if your well is going dry?

If you get your water from a private well, there are some warning signs that your well may be going dry. The first sign is the water is sputtering out of the tap, indicating air pockets in the well. The second sign is the water is not clear, but muddy or filled with sediment.

How do I install a pump saver?

1:066:23Symcom 231-Insider-P Pump Saver - YouTubeYouTubeStart of suggested clipEnd of suggested clipSo anyhow so what you'll have to do is you've got this little diary diagram on the QD boxes l1 l2.MoreSo anyhow so what you'll have to do is you've got this little diary diagram on the QD boxes l1 l2. So we're going to need to pull l1. Actually clean out of there and grab the wire strippers. Here.

How do you use a pressure washer pump saver?

0:391:54How To Store a Pressure Washer Using Briggs and Stratton Pump ...YouTubeStart of suggested clipEnd of suggested clipYou know simply hold the button down to dispense the lubricant. And until it basically comes out ofMoreYou know simply hold the button down to dispense the lubricant. And until it basically comes out of the outlet. So you'll hold it down. Until you see the look in on how the element of the pump.

How long do well pump units last?

Not all well pumps last the same amount of time, and their average life expectancy can vary anywhere between one and ten years.

How do I improve my well pump’s life expectancy?

To make your pump last longer, it is crucial to assess your pump for damages and conduct any repairs immediately. If any components show wear or si...

What should I do if my well runs out of water?

If your well has run dry or there isn’t water in your faucets, you have three options. You can: Lower your pump to reach the lower water table Deep...

What do I do when the pump loses pressure?

The main reasons that your pump could be losing pressure include: Water storage tank capacity The size of the water pump, or A faulty check valve/f...

How do I check the foot valve on a shallow well pump?

After you remove the foot valve from the end of the pipe, check to see for signs of freezing or rust near the valve end.

What is shallow well pump?

Shallow well pumps are non-submersible pumps that are placed outside the well. If you have a high water table – or in other words, your underground water is closer to the surface – a shallow well pump system can efficiently work to draw water from your well.

What is priming a well pump?

Priming is the process of running water through your pump to generate the right amount of pressure for a smooth operation. Priming is an integral part of maintaining a well pump, mainly if it has not been used for a while.

What is a submersible pump?

Submersible pumps are primarily used for deep wells and low water tables and are submerged in the well water. Their mechanism involves pushing water upwards instead of pulling it in.

How many volts does a well pump need?

It can easily fit wells at least 5 inches in diameter and requires a minimal amount of 115 volts. While this model can be used for homes, it is an ideal fit for industrial use.

How deep is a well pump?

This is a submersible well pump for deep wells of up to 250 feet in depth. Its stainless-steel shell keeps the pump corrosion free for a long time – making it a durable and robust well pump model.

How big is a well casing?

Even though the range is extensive, most well casings range between 5 and 6 inches. This can help you determine the diameter of your pump.

What is a well report?

Well reports contain technical information such as the well diameter, the mineral composition of the well water, and the expected water yield. To procure such a report, you can check to see if a previous owner has one, and can give you a copy. If not, you can contact a professional driller, and get a new well water report.

What is a pump saver?

A pump saver device, of which there are several device types using different methods, is designed to protect the pump from damage if well flow rate is poor, by preventing the pump from running from then on (thus being damaged) by recycling water through a tailpiece as pump runs - until the well recovers.

What is a circuit breaker in a well pump?

Electrical circuit breakers or fuses found in the electrical panel feeding the electrical circuit for the pump motor and its controls are designed to turn off electrical power to a water pump or well pump circuit if the circuit is drawing excessive current at an unsafe level.

Why does my pump 120 overheat?

Pump overheat damage is caused when water stops flowing and the pump continues to run. This causes the water in the pump to get very hot resulting in total system failure. The POP 120 shuts off the pump before overheat damage occurs, keeping the pump system safe until repairs can be made.

Why is my well pump running?

Watch out: A water pump or "well pump" can be damaged by conditions that cause the pump to run continuously, particularly if the pump is running "dry" - without water passing through its mechanical parts. The result can be the need for a costly repair or for pump and control replacements. [Click to enlarge any image]

What is pump cycle?

A ‘pump cycle’ is the start and stop of a pump. Some applications may cause a pump to ‘cycle’ or start and stop repeatedly in a short period. This repetitive starting can cause motor, control or pump failure and can also cause pressure fluctuations that may lead to failure of the pipe or other fittings.

What does underload mean on pumptec?

The PumpTec controller uses three indicator lights to indicate power, electrical load, and voltage levels. An "underload" indication can indicate that the well is dry while an "overload" indication typically means that there is a problem with the pump motor, causing it to draw excessive current .

Can a water pump stop running?

WATER PUMP WONT STOP RUNNING. Ernie, Yes there are more sophisticated water pump controls with sensors that can shut off the pump it it's pumping air. Typically these work by monitoring the current draw of the pump, the pump motor temperature, or actual water flow.

Customers who bought this item also bought

Well Pump Wire Splice Kit, Submersible 3M Dual Wall Heat Shrink Tubing and Copper Connector for 4 Wires, 10#12#14 AWG.

Special offers and product promotions

Create your FREE Amazon Business account to save up to 10% with Business-only prices and free shipping.

Have a question?

There was a problem completing your request. Please try your search again later.

Customer reviews

There was a problem filtering reviews right now. Please try again later.

Customers who bought this item also bought

Well Pump Wire Splice Kit, Submersible 3M Dual Wall Heat Shrink Tubing and Copper Connector for 4 Wires, 10#12#14 AWG.

Special offers and product promotions

Create your FREE Amazon Business account to save up to 10% with Business-only prices and free shipping. Register today

Have a question?

There was a problem completing your request. Please try your search again later.

Product Description

SymCom Model 233P-1.5 PumpSaver Plus. INCLUDES ENCLOSURE. PROTECTS FROM 1/3 to 1.5HP; With NEMA Enclosure, THIS MEANS FOR OUTDOOR USE 24/7 pump monitor designed to protect single-phase pumps from dry-well, dead-head, jammed impeller, overvoltage and undervoltage conditions. The PumpSaver Model 233P protects 230V 2 or 3 wire pumps; From 1/3-1.5hp.

image
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z 1 2 3 4 5 6 7 8 9