How far apart should outlets be placed from each other?
Outlet Spacing in Kitchens. In kitchens, electrical outlets should be placed no farther than 48 inches apart, so that no point on the countertop is more than 24 inches away from a receptacle. Any countertop 12 inches wide or more should have an outlet on the wall behind the countertop.
How high should an outlet be above a garage floor?
There is no height requirement for garage receptacles. Most around here set them at about 48". Ignition sources have to be elevated above 18" in garages. That's basically because of the potential for combustible heavy vapor buildup. The challenging gray area is the mysterious definition of sources of ignition.
How far apart should outlets be in a room?
Wall receptacles may be placed no farther than 12 feet apart on any wall surface. Any wall section wider than 2 feet must have a receptacle. Dining rooms usually require a separate 20-amp circuit for one outlet used for a microwave, entertainment center, or window air conditioner.
How high off the floor should a range outlet box be?
When installing an electrical outlet outdoors, the box must be at least 6 1/2 inches above grade, and in garages, they should be 18 inches or more above the floor, as measured from the center of each box.
How high should outlets be in a garage?
Many contractors place outlets 12 to 18 inches above the floor because that height suits most people, not because the NEC demands it. That being said, the American Disabilities Act expects homeowners to place wall receptacles at least 15 inches above the floor.
What is code for outlets in garage?
As of the 2017 NEC, newly constructed garages need at least one dedicated 120-volt 20-amp circuit that serves only the garage. This circuit may also power receptacles mounted on the exterior of the garage.06-Dec-2021
Where should outlets be placed in a garage?
Standard outlets are spaced apart, a foot or so above the floor. If you plan on adding workbenches along the walls, you'll also want outlets at the same above-the-counter height as in a kitchen. This way, you won't have to drop a cord behind the bench top.
What is code for outlets off the floor?
Electrical receptacle outlets on branch circuits of 30 amperes or less and communication system receptacles shall be located no more than 48 inches (1219 mm) measured from the top of the receptacle outlet box nor less than 15 inches (381 mm) measured from the bottom of the receptacle outlet box to the level of the ...
Do you need GFCI outlets in garage?
GFCI protection is required for 125-volt to 250-volt receptacles supplied by single-phase branch circuits rated 150 volts or less to the ground. GFCI receptacles are required in bathrooms, garages, crawl spaces, basements, laundry rooms and areas where a water source is present.
How many outlets can be on a 20 amp circuit in a garage?
ten outletsThe answer to the question how many outlets on a 20 amp circuit is ten outlets. Always comply with the 80% circuit and breaker load rule, allowing a maximum load of 1.5 amps per receptacle. Remember that your circuit, wire sizes, and outlets must be compatible to avoid overheating and electrical hazards.
Where should I put my 220v in my garage?
59 second clip suggested8:20How to Install 220v outlet in Garage the Easy Way = Run - YouTubeYouTubeStart of suggested clipEnd of suggested clipSo the host can reach any vehicle I'm working on. And it's more than three feet from this waterMoreSo the host can reach any vehicle I'm working on. And it's more than three feet from this water spigot. Using a measuring tape I figured how far my outlet would be from this corner.
Is 15 amps enough for a garage?
Since it's a garage, I'd install a single 20 ampere circuit at the very least. A 15 ampere circuit would be fine for lighting, but you'll find it quite limiting when/if you start plugging in tools/equipment.19-Sept-2016
Why do electricians install outlets upside down?
Electricians may position the outlet in an upside-down position so that you can quickly identify the switch-controlled receptacle. Since it stands out visually to most people right away – it provides convenience to the occupants to easily remember which outlet is switch controlled.05-Jan-2020
How high should a switch be off the floor?
48 inchesFor a majority of rooms, builders tend to place the bottoms of light switches 48 inches above the floor. This is a comfortable height for most home dwellers when sitting or standing, plus it makes it easier to install switches during construction.10-Jun-2020
What is the distance between outlets?
The maximum spacing between receptacles, according to the National Electric Code (NEC), has been set at 12-feet since 1956--with no point along a wall being more than 6-feet from a receptacle. The logic behind that number is that an appliance with a standard length cord could then be plugged-in anywhere along the wall.09-Oct-2018
How close can an outlet be to a corner?
Similarly, how close can an outlet be to a corner? The National Electrical Code specifies that you must have an electrical outlet (receptacle) within 6 feet of the corner of any wall and no more than 12 feet separating receptacles on the same wall (6/12 outlet rule). That of course is the minimum requirement for living space .
How high is a GFCI breaker?
One receptacle is required at the front and rear of the house and at a maximum height of 6 feet 6 inches above grade (ground level).
Why do ignition sources have to be elevated above 18"?
Ignition sources have to be elevated above 18" in garages. That's basically because of the potential for combustible heavy vapor buildup. Click to see full answer.
How high should a garage outlet be?
Most garages are going to have some standard, floor level outlets places at 12-16″ above floor level but you will definitely want to consider adding some workbench level outlets if you are going to have a workshop of any kind in your garage.
Do you need a breaker for 220V?
For things that draw more amperage, like your air compressor, consider the benefits of having them on their own circuit. Obviously, anything pulling 220 V is going to need its own breaker as well.
Can you put a washer and dryer in a garage?
People used to just store their cars in garages and that was about it. For some houses, it makes a great place to put the water heater or washer and dryer too. When you are in a position to add outlets to your garage, it pays to think ahead and try to anticipate any future needs.
Can you wire two outlets at once?
You aren’t likely to be in two places at once so one idea is to wire your receptacles so they alternate between circuits. You could also wire upper and lower portions of each two gang outlet separately. That way if you have two things plugged in at the station you are working on, you aren’t as likely to blow a breaker.
Can you have lighting and overhead outlets at the same time?
Lighting and overhead outlets are two different entities but they can be planned for at the same time. Think about the ceiling and what it needs to do for you.
How high should a garage receptacle be?
There is no height requirement for garage receptacles. Most around here set them at about 48". Ignition sources have to be elevated above 18" in garages. That's basically because of the potential for combustible heavy vapor buildup. The challenging gray area is the mysterious definition of sources of ignition.
Why do garages have to be elevated?
Ignition sources have to be elevated above 18" in garages. That's basically because of the potential for combustible heavy vapor buildup. The challenging gray area is the mysterious definition of sources of ignition. In my opinion, this code was put in place to prevent water heater installation (or furnaces) on the garage floor back before they mandated the change to sealed combustion water heaters (which an ICC memorandum now allows on garage floors).
Is a garage considered a hazardous area?
I'm not absolutely certain, but I believe that a garage that has the ability to store motor vehicles is a classified (hazardous) area.
Can a water heater be installed on the floor?
This is why water heaters and furnaces are installed on platforms, and not directly on the floor.
Is there an 18 inch rule for home inspection?
Don't know about other sources of speculation about an 18 inch rule, but a lot of home inspectors believe such a rule exists because it is shown in illustrations in the Carlson Dunlap training materials and reproduced in the "Illustrated Home" book published by the same source (illustration 622) - it's in there, however, because it's a Canadian requirement, it's not present in the NEC.
Can an electrical receptacle be an ignition source?
If true, this means that there cannot be any source of ignition within 18" of the floor. Electrical receptacles and switches are considered a source of ignition unless they're listed for use in classified atmospheres.
How high should an electrical outlet be in a garage?
Re: Garage electrical outlet location: "In the garage electrical outlets should be 18" or more above floor level."
How far away should electrical outlets be from a tub?
Tub-Shower clearance: Keep electrical receptacles at least three feet (one meter) away from a tub or shower. Electric baseboard clearance: Keep electrical outlets offset above and to the side of vanity sinks, not right over the sink (left hand sketch below)
How many receptacles on a 15-amp circuit?
Reader question: How many receptacles can be wired To one 20 amp circuit No. 12. Wire - John K.
Why are electrical receptacles 18" above the floor?
IMO the origin of the 18" minimum electrical receptacle height above the floor in residential garages is the same reason we elevate heating appliances: avoiding blowing up vehicle gasoline fumes presumably collected at floor level. Actually I see electricians putting the receptacles at 36-48" for reasons of easy access - also a practice not a code spec.
How high above floor level for garage door?
After all, we regularly install a ceiling-mounted receptacle to power garage door operators. One electrician cited 5'6" maximum above floor level for receptacles meeting the 6' horizontal spacing rule (NEC 210-52) [4].
What is an electrical receptacle?
Electrical receptacles (also called electrical outlets or "plugs" or "sockets") are simple devices that are easy to install, but there are details to get right if you want to be safe.
How far away from an electrical outlet is the nearest electrical receptacle?
In general electrical receptacles are installed along building walls such that at no point along the wall is the distance to the nearest electrical receptacle more than six feet - i.e. receptacles can be spacesd 12 ft. on center.
How many receptacles are needed for a garage?
A minimum of one 120-volt 20-amp receptacle circuit is required for a garage, per National Electrical Code [NEC 211.10 (C) (4)]. We often see only one receptacle in a garage, which would meet the minimum standard.
Where is the GFCI device in garage?
One of the garage receptacles will typically have a GFCI-device in the center —with the two buttons in the center for “TEST” and “RESET.”.

Types of Outlets That Should Be Considered For A Garage
Breakers and Garage Outlet Placement
- When you discuss the electrical plan for your garage with your electrical contractor, one thing you shouldn’t forget to talk about is breakers. The last thing you need is to be working with the table saw when the air compressor kicks on and blows a breaker leaving you in the dark. You aren’t likely to be in two places at once so one idea is to wire your receptacles so they alternate betwe…
Future Proofing Your Garage
- The final thing to consider is the type of outlets you want to add. The changes in technology over the years continue to astound me. Just last year I paid to have 15 Amp Decora Combination Duplex Outlet and USB Chargers added to my apartment. I can’t tell you how convenient it is to have USB’s available where I need them. It’s not just USB outlets though, smart switches and sm…
Related Questions
- What height should outlets be in a garage?This is entirely dependent on what you need to plugin. Most garages are going to have some standard, floor level outlets places at 12-16″ above floor level but you will definitely want to consider adding some workbench level outlets if you are going to have a workshop of any kind in your garage. How do I in...