How far apart should electrical outlets be on kitchen countertops?
In kitchens, electrical outlets should be placed no farther than 48 inches apart, so that no point on the countertop is more than 24 inches away from a receptacle. Any countertop 12 inches wider or more should have an outlet on the wall behind the countertop.
How far should the outlet be from the range?
E.g. is 9" diagonal from the range okay, 6" lateral distance. Please note this is not the outlet to power the range but just a countertop receptacle. Code doesn’t restrict the location of a range receptacle. They are normally behind the range location most are below the counter height so the receptacle is not visible when the range is in place.
What is the electrical code for distance between gas line and outlet?
The is no electrical code for distance of receptacle from gas line. I don't know about the gas code. Re: Distance between gas line and electrical outlet. Only in Canada.
How far should a receptacle be from the wall?
Article 210.52 (A) (1) states: Receptacles shall be installed such that no point measured horizontally along the floor line of any wall space is more than 6ft from a receptacle outlet. This spacing is chosen so that a lamp, computer, television, or other appliance will never be more than 6 feet away from an electrical outlet.
Where should a range outlet be placed?
The receptacle should be mounted based on the range manufacturer's specifications. This is usually on the back wall behind the range, several inches above the floor, and off-center in the cabinet space for the range. Floor-mounting for the receptacle is preferred for some ranges.
How far does outlet need to be away from kitchen sink?
This applies even if there isn't a nearby sink, such as on a bar or island. Additionally, no point on the wall should be farther than 24 inches from an outlet in either direction (meaning 4 feet total between outlets), so you must have an outlet within 2 feet of the kitchen sink.
How close can you have electrical outlets?
The US National Electrical Code, Section 210.52, states that there should be an electrical outlet in every kitchen, bedroom, living room, family room, and any other room that has dedicated living space. They must be positioned at least every twelve feet measured along the floor line.
How high should electric stove outlets be?
NEC Code 210.52(c)(5) – Range Appliance Application: Receptacles are to be mounted no more than 20 inches above the kitchen counter top. Installation Note: Typically the 220volt range receptacle is mounted near the floor, just above the baseboard.
What is code for electrical outlets in kitchen?
In kitchens, electrical outlets should be placed no farther than 48 inches apart, so that no point on the countertop is more than 24 inches away from a receptacle. Any countertop 12 inches wide or more should have an outlet on the wall behind the countertop.
How close can a GFCI be to a kitchen sink?
Previous Requirement If your house was built or wired before 1996, it is a good idea to check if it has GFCI and to have these circuits installed if it doesn't. This should explain why all of your outlets are at least 6 feet from the sink and why you should not install any outlets closer than that.
Does every outlet in a kitchen need to be GFCI?
Not all your kitchen outlets need to be the GFCIs, but they are required to be if they're within six feet of a kitchen sink or if they serve a countertop. Near laundry room sinks. Any receptacles within 6 feet of a sink or washing machine should be GFCIs.
How many outlets should a kitchen have?
The NEC says every piece of counter 12 inches or wider must have an outlet over it. In addition, there must be at least one outlet every 4 feet.
Is it OK to put an outlet under a window?
Yes. As long as you have part of the wall under your window (your window doesn't go to the floor) then it is treated like any other wall in your house.
Can you use a 30 amp breaker for a electric stove?
Because most stoves are 240 volts, it is best to use a double-pole circuit breaker on a dedicated circuit inside your electrical panel. Electric stoves often require a 30 to 60 amp circuit breaker.
What is outlet height code?
Electrical receptacle outlets on branch circuits of 30 amperes or less and communication system receptacles shall be located no more than 48 inches (1219 mm) measured from the top of the receptacle outlet box nor less than 15 inches (381 mm) measured from the bottom of the receptacle outlet box to the level of the ...
Do you need a special outlet for electric range?
When it comes to electricity usage, an electric stove is a powerhouse. Consequently, you can't just plug them into the standard 110-volt outlets that are most common in the United States—most stoves require a special 220-volt outlet instead.
How far apart should outlets be in a kitchen?
Outlet Spacing in Kitchens. In kitchens, electrical outlets should be placed no farther than 48 inches apart, so that no point on the countertop is more than 24 inches away from a receptacle. Any countertop 12 inches wide or more should have an outlet on the wall behind the countertop.
How far away from an electrical outlet should a lamp be?
This spacing is chosen so that a lamp, computer, television, or other appliance will never be more than 6 feet away from an electrical outlet.
How many amps does a general purpose outlet need?
General-purpose outlet receptacles should have a rating that is appropriate for the amperage of the circuit they serve. Generally, these household circuits will provide 15-amps or 20-amps of service, and the outlet receptacle rating should not exceed this amperage. Check the circuit's breaker in the service panel to find out whether it is 15 amp ...
What is a tamper resistant outlet?
In tamper-resistant outlets, a spring-loaded gate within the outlet prevents young children from pushing objects such as knives into the outlet slots.
What is a 20 amp receptacle?
A 20-amp receptacle is designed to accept the special plug on heavier-use appliances, and if such an appliance plugs into a 15-amp circuit, there is a danger of drawing too much power and overloading the circuit.
How many outlets are needed in a 10 foot wall?
Again, you are allowed to place an outlet in this space if you so choose. Hallways more than 10 feet long must have at least one electrical outlet, preferably at the mid-point.
Do residential outlets have to follow the NEC?
Most, but not all, follow the recommendations of the national model code, the NEC.
Can a refrigerator be on its own circuit?
The fridge has to be on its own circuit. This is part of the NEC and has been for years. You may have to pull new wires. Click to expand... Only in Canada. The OP is in USA. The fridge can be on the counter small appliance circuit if he wants. The is no electrical code for distance of receptacle from gas line. I don't know about the gas code.
Can a refrigerator be on a small appliance circuit?
I don't know about the gas code. Click to expand... You are correct THE NEC states that the refrigerator can be on one of the small appliance circuits BUT it has become convention to put it on a dedicated circuit because many inspectors require it.
How wide is a receptacle outlet?
A receptacle outlet shall be installed at each wall counter space that is 12 inches. (300 mm) or wider. Receptacle outlets shall be installed so that no point along the wall line is more than 24 inches (600. mm) measured horizontally from a receptacle outlet in that space.
How high above countertop should a receptacle be?
Receptacle outlets shall be located above, but not more than 20 inches (500. mm above), the countertop. Receptacle outlets rendered not readily accessible by appliances fastened in place, appliance. garages, or appliances occupying dedicated space shall not be considered as these required outlets.