by Mack Bernhard Published 3 years ago Updated 3 years ago

Kitchen Electrical Code: Everything You Need to Know

  • GFCI-Protected Small Appliance Circuits. Requirement: Provide at least two 20-amp, 120-volt circuits to supply power to...
  • Basic Lighting Circuit. Requirement: Provide at least one 15-amp, 120-volt circuit feeding a ceiling fixture, recessed...
  • Distance Between GFCIs Over Countertops. Requirement: You should allow no...

Kitchens: All receptacles serving countertop areas and any receptacle within 6 feet of a sink must have GFCI protection. Also, the receptacle supplying a dishwasher should be GFCI-protected.27-Sept-2021

Full Answer

How many GFCI do I need in kitchen?

You only need one GFCI as long as it's installed as the first outlet in the circuit (or at least upstream of anything else that needs protection) and wired correctly. OUr inspetor required every outlet in the kitchen to be GFCI protected. Click to read in-depth answer. Thereof, how many GFCI do I need in my house?

What are the electrical requirements for a kitchen?

  • 1/2 HP garbage disposal – 2.5 amp (WasteMade garbage disposer)
  • dishwasher – 9 to 12 amp
  • microwave – 4.5 to 12 amp

Are GFCI outlets required in kitchens?

Not all of the receptacles in kitchens, bathrooms or other required locations need to have a GFCI outlet. Because of the way that the outlets function, only the first receptacle in the line—the one closest to a source of water—must have a circuit interrupter.

When and where are GFCI receptacles required?

The National Electric Code (NEC) requires the installation of GFCI outlets in new construction in areas where electrical outlets are in close proximity to water. Older homes are not required to have GFCI outlets unless the wiring is being updated, but it’s a good idea to install them anyway.

How far away from a sink should a GFCI be installed?

The revision of the NEC done in 2005 requires that all receptacles within 6 feet of a sink or a wet bar need to be with a working GFCI protection installed.

What outlets need GFCI protection?

According to the Code, all outlets that are rated at 15 and 20 amperage and 125V that are installed in the following areas need to have GFCI protection. Garages and accessory buildings. Bathrooms, jet tubs, pools, and spas. All outdoor areas. Kitchens and nearby sinks.

How old do you have to be to remove plastic receptacle caps?

In comparison, the plastic receptacle caps are not safe and easily removed by children between the ages of 2 and 4. There are tamper-resistant outlets that do have built-in GFCI protection (and also AFCI protection, too).

How to tell if a GFCI is a fault?

You can easily distinguish a GFCI outlet by the two buttons (a TEST and RESET button) that are located on the outlet itself. There should also be a label reading GFCI on it as well.

Why is GFCI needed in laundry?

Therefore, GFCI protection is needed to protect against electrical shock.

How many amps does a jet tub need?

GFCI protection is needed for any outlet up to 30 amps and 125-volt that are located within 6 feet of the jet tubs. Jet tubes, hot tubs, hydro-massage tubs, Jacuzzi tubs, and whirlpools are required by the NEC to have proper GFCI protection. The requirement was introduced with the 1987 revision of the NEC.

Where is the GFCI reset on a dishwasher?

The GFCI reset for the dishwasher is generally located on the Dual-Function breaker inside the panel box. However, some older homes may only have a GFCI breaker or no GFCI protection at all.

How many inches between countertop receptacles?

Requirement: You should allow no more than 48 inches between countertop receptacles . Why: The intent is that a homeowner should not be tempted to stretch a cord more than 24 inches (i.e., half of the required 48 inches) to plug in a small appliance.

Why is less amperage required for kitchen lighting?

Why: Less amperage is required for light fixtures; however, if you desire more lighting, you will have to bring up the amperage, and other attendant factors, such as wire gauges, etc. , to meet those needs. The "one" requirement is the bare minimum to ensure that kitchens have at least some kind of permanent lighting.

Why 20 amps?

Why: The 20 amps are required (vs. 15 amp) for the higher power requirements found in kitchens. Think toaster ovens, blenders, and mixers. The "two" part of this requirement spreads out the coverage area, though not the total load, as both can be on the same circuit. Providing frequent plug-in points has long been a mainstay of the NEC ...

Is a dedicated dishwasher GFCI?

Should not be GFCI. Why: Dedicated is the key word. This means that the dishwasher gets its own circuit and cannot accidentally trip off (at the circuit level ), thus turning off power to other areas of the kitchen. Accidental tripping is also the reason for it, not being GFCI.

Dwelling Units 210.8 (A)

All 125- through 250-volt receptacles in the following locations that are supplied by single-phase branch circuits rated 150 volts or less to ground are required to have GFCI protection for personnel.

Other Than Dwelling Units 210.8 (B)

All 125-volt through 250-volt receptacles supplied by single-phase branch circuits rated 150 volts or less to ground, 50 amperes or less, and all receptacles supplied by three-phase branch circuits rated 150 volts or less to ground, 100 amperes or less, installed in the following locations are required to have GFCI protection for personnel.

Dwelling Units 210.8 (A)

All 125-volt, single-phase, 15- and 20-ampere receptacles in the following locations are required to have GFCI protection for personnel.

Other Than Dwelling Units 210.8 (B)

All single-phase receptacles rated 150-volts to ground or less, 50 amperes or less and three-phase receptacles rated 150-volts to ground or less, 100 amperes or less installed in the following locations are required to have GFCI protection for personnel.

Kitchens Branch circuits

At least two small appliances dedicated 20-amps branch circuits to serve kitchen counter top’s outlets and dinning area. (NEC 210.51 (B) (1)) & (NEC 210 (B) (3)).

AFCI Kitchen outlets

All 15- and 20- Amps branch circuits serving outlets located in the kitchen and dinning room shall be protected by AFCI protected in addition to GFCI protection where it is required. (NEC 210.12 (A)).

Kitchen Remodel lighting requirements

One 15- or 20- Amps branch circuit to serve kitchen pendant, and recessed lighting.

What appliances do you need to wire in a kitchen?

When it comes to large appliances in your kitchen, the NEC usually requires dedicated wiring for: Electric range, cooktop, or oven; Dishwasher and garbage disposer (make sure that these have dedicated circuits if together their rating exceeds one circuit’s capacity);

How many amps for kitchen appliances?

Kitchen Wiring For Small Appliances. Every kitchen wiring plan has to include two 20-amp small appliance circuits, which serve all countertop receptacles and most wall receptacles, especially if you have them located in the dining room and pantry as well.

What are the requirements for a kitchen sink?

When it comes to receptacles, there are several rules you need to consider. Here is what you will find in terms of requirements in the NEC: 1 Receptacles are required for all countertop spaces of 12 inches and more. 2 Receptacles should not be mounted face up and no more than 20 inches above countertops. 3 All kitchen countertop receptacles are required to be GFCI. 4 The first receptacles on either side of the sink has to be within the first 2 ft. of the sink basin.

How many inches are receptacles required?

Here is what you will find in terms of requirements in the NEC: Receptacles are required for all countertop spaces of 12 inches and more.

How many circuits are needed in a kitchen?

In a modern kitchen, you will need to have seven or eight circuits, as opposed to a bedroom, for instance, where one general-purpose lighting circuit is enough.

How many volts does a 50 amp range need?

A typical electric range requires a dedicated 240/250-volt, 50-amp circuit. So, you will need to install a 6/3 NM cable (or #6 THHN wire in a conduit) to feed the range. For gas range, only a 120/125-volt receptacle will be required to power the range controls and vent hood.

What are the main types of kitchen wiring?

All kitchen wiring plans have three main circuit types: small appliances, general lighting and permanent (also known as large) appliances. The entire lighting in the room is supplied by the general lighting circuit.

What is the new NEC 2020?

The NEC 2020 code changes for GFCI protection allow for the utmost safety for families and workers alike. Let’s get into some of the nitty gritty details to give you some knowledge on what you should know about the changes.

Why is the GFCI code changed to 125V?

The reason for the NEC 2020 code change for GFCI protection to include 125V through 250V receptacles (outlets) is because there have been a handful of fatal incidents reported where children were electrocuted by dryer machines and other big appliances in the specified locations utilizing 250V receptacles. To keep people safe, the NEC decided that ...

What is a GFCI in NEC?

A GFCI (Ground Fault Circuit Interrupter) is a device that protects people from electric shock in their electrical system. It works by detecting a fault in ...

What is the NEC?

The NEC (National Electrical Code) is a set of standards for safety and compliance with the installation of electrical wiring/equipment in the U.S. These are the guidelines that our licensed and insured electricians at KB Electric LLC must follow for the safety of you and your family. They also allow us to be safe in the field as well.

Do basements need GFCI protection?

To keep people safe, the NEC decided that these higher amperage outlets needed GFCI protection. Both finished and unfinished basements are required in dwellings to have GFCI protection. Before the 2020 revisions, only unfinished basements required GFCI protection.

Do you have to keep your home up to code?

Not only is it recommended to keep your home up to code for safety reasons, but most townships will require these things to be done for home renovations, addition work, etc. Check with your township to find out which NEC year they use for safety and compliance.