Ge Compatible Breaker
- Square D. Square D and GE breakers are not interchangeable. ...
- Cutler-Hammer. Cutler hammer breakers are interchangeable, not only with GE but also Siemens, Homeline, and Murray, to mention but a few.
- Eaton. Eaton makes classified breakers that work in GE panels. ...
- Siemens. You can interchange Siemens breakers with GE. ...
- Murray. ...
- Challenger. ...
- Westinghouse. ...
Full Answer
How to identify GE Power break circuit breakers?
- The most common breakers used in homes.
- Protect one energized wire.
- Supply 120V to a circuit.
- Handle 15- to 30-amps.
- Available in three types: Full size (1-inch wide), half size (1/2-inch wide) and twin/ tandem (1-inch wide with two switches and controls two circuits).
Which breakers are compatible?
While you now know that Eaton breakers, Westinghouse breakers, Square D breakers, and Cutler-Hammer breakers are largely compatible, you still need to find the exact models you need for your facility. Click to see full answer. Similarly, are Cutler Hammer and Siemens breakers interchangeable?
Are Siemens Breakers compatible with GE boxes?
Siemens breakers can be used in GE breaker boxes, and they are generally known to be compatible. Match the size and voltage requirements when using Siemens breakers, as using the wrong breakers can have dangerous results. This could lead to a meltdown of the breaker box, and even a fire.
Are GE and Eaton Breakers interchangeable?
Eaton's UL classified breakers are designed and tested to be both mechanically and electrically interchangeable with circuit breakers manufactured by General Electric, Thomas & Betts, ITE/Siemens, Murray, Crouse-Hinds, and Square D.
What breakers are interchangeable with GE?
Siemens breakers can be used in GE breaker boxes, and they are generally known to be compatible. Match the size and voltage requirements when using Siemens breakers, as using the wrong breakers can have dangerous results. If the wrong breaker is used it could fail to break (shut off power) during a surge.
Are GE and Eaton breakers interchangeable?
Both breakers fit. Only if the model number of the breaker is listed by the box as acceptable. Nope.11-Mar-2020
Will Eaton breaker work in GE panel?
TLDR: They're all wrong. Swap with a GE or classified breaker (e.g. Eaton CL not BR).18-Nov-2019
Are GE and Square D breakers interchangeable?
The Homeline breakers are made to fit in most "interchangeable" panels, such as GE, Bryant, Murray, ITE, etc. However, Square D added a small protrusion on their bus bars to reject those other breakers from being installed in the Homeline panels.23-Feb-2020
Does GE make quad breakers?
Non CTL Quadplex Breaker Without Rejection Tab, 2-Pole, 10 kAIC, 2-Pole 20 Amp Outer Indep Trip and 2-Pole 40 Amp Center Indep Trip, Requires (2) 1-inch spaces, Wire Size #14-4, 12...
Can I use a Square D breaker in a Cutler Hammer panel?
Both of the breakers were able to fit. If the model number is listed by the box, it's acceptable.
Will GE breakers fit Murray box?
They are physically interchangeable with Murray and other brands, but remember to check your local code to see if it's legal to install. Not all breakers that fit in your panel are legitimate and trusted. The three products, as mentioned earlier, can replace Murray.02-Mar-2022
What breakers are interchangeable?
Specified breakers are breakers that have been tested and listed for a panel by the manufacturer. Interchangeable breakers are breakers that have been tested in the panels that they are approved for and are similar to specified breakers, typically by a third party such as Underwriter's Laboratory (UL).10-Jun-2021
What breakers are compatible with Eaton CH?
While you now know that Eaton breakers, Westinghouse breakers, Square D breakers, and Cutler-Hammer breakers are largely compatible, you still need to find the exact models you need for your facility.08-Aug-2018
What breaker is compatible with Square D?
Square D QO breakers are compatible with QO breaker boxes and CSEDs. Each ANSI-certified and UL-listed. Homeline circuit breakers are built with the same Square D brand quality you have come to expect at a price that makes them the best value in their class.
What is GE Q line?
General Electric Q-Line Series GE manufactured products often introduce revolutionary approaches to distrusting and protecting the electrical circuitry. GE's Q-Line circuit breakers are compact and built for continuous, long-term protection against damage from thermal or overcurrent faults.21-Mar-2017
How do I know what type of circuit breaker to buy?
Circuit breakers have markings stamped on the side of them and are usually located inside the panel cover door. There is a label that will tell you what type of breaker is needed for installation in that particular panel.30-Nov-2021
What is classified breaker?
A classified breaker is manufactured to generally fit several different panelboards and has met so called standards by a 3rd party like uL Labs for use in different panelboards. Bottom line the Square d homeline breaker shown does not belong installed in that GE panel.
Can a square d qo breaker fit in a homeline panel?
Only square d qo breakers will fit in that panel period,The homeline panels will fit other breakers but it shouldn't be done except in a temp/emergency situation.
What are breakers on a panel?
Breaker types which are listed on the panel's labeling, these will be made by the same manufacturer and the same type, and UL- listed. Breaker types which are contemporary to your panel's labeling, but again are still the same manufacturer, and they state they will work in your panel, or substitute for breakers which are labeled for use in your ...
Why change out GE bus bar?
Change them out if: They are warmer than the GE's, are melting or deforming on any of their surfaces or are causing or showing any corrosion at their connection to wiring or to the bus bar.
What is a classified UL?
Classified is UL's way of saying these are not OEM breakers and do not have the benefit of the OE's expertise and trade-secret knowledge, but they do pass safety testing. Keep in mind that a manufacturer's Classified breakers are different breakers than the OEM breakers they make for their own panels.
Is Square D a classified breaker?
On your panel, we can strike out the Square D breakers immediately. Square D is absolutely opposed to "Classified" breakers. They refuse to make classified breakers for competitor panels, and they object to the use of Classified breakers in their panels (not that they have anything to say about it). So the Square D "HOMeline" breakers are out-of-place because Square D says so: You are using this breaker in contradiction to its labeling and instructions, which violates NEC 110.3 (B).
Is UL listed a problem?
FYI, UL-Classified is a problem, but UL-Listed is not. UL-Classified is the cheap garbage route by only partially meeting the safety standard in just very specific tests. UL-Listed is the full boat approval of the entire safety standard.
Does Siemens make QO panels?
Siemens does make classified breakers. They make the QD type for Square D "QO" panels, and the MSQ type also for Square D "QO" panels. Now, Siemens' website just burned down so Google is useless (every page is 404). But from Google's view of their pages, it's clear they don't make UL-classified breakers for GE panels.
What Circuit Breakers Are Compatible With Square D?
Siemens breakers can work in the place of square D. The brand has a QD series breaker that can work in square D panels. The breakers are versatile enough to work in most interchangeable panels.
Can You Mix Different Brands Of Breakers?
Square D has warned its consumers against using breakers from different brands. If an accident occurs because you used a different brand, the company may void your warranty. Keep that concern in mind.
What does specified breakers mean?
Specified breakers mean the manufacturer has tested the breakers in the panel and listed them to be used in that panel. You have probably noticed “UL Classified” and interchangeable circuit breakers around the market.
Is using breakers not listed or labeled a violation of the electrical code?
They site the National Electrical Code (NEC) Section 110-3 (b), which states that using breakers not listed or labeled is a code violation. Their argument is for public safety drawing evidence from past accidents due to the use of Classified breakers in their panel.
Can you use UL classified breakers in panelboard?
Otherwise, just replace the same type of existing breakers in the box. Manufacturers would want to specify their own breakers for use in their panelboards for obvious financial reasons. However, remember you have options with UL Classified breakers like the chart above. Some electricians use Classified breakers for obvious reasons, whether for price, availability, or convenience. But which ever circuit breakers you go with, make sure to install them safely.
Can UL Classified breakers be used for panels?
These breakers meet UL and NEC code regulations. UL has stated that people must adhere to all manufacturer supplied instructions. Moreover, UL also stated that Classified breakers can be used for their approved panels. ( Source: UL Marking and Application Guide Panelboards ). On the note of warranty void, manufacturers cannot void their warranty if the replacement part has proven to be safe by a third-party, for instance UL (Magnusson-Moss Warranty Act).