- 391. GEQ-Line 30 Amp 1 in. Double-Pole Circuit Breaker. ...
- 464. GEQ-Line 40 Amp 2 in. Double-Pole Circuit Breaker. ...
- 311. GEQ-Line 15 Amp 1 in. ...
- 171. GEQ-Line 125 Amp 2 in. ...
- 265. GEQ-Line 15 Amp 1/2 in. ...
- 317. GEQ-Line 20 Amp 2 in. ...
- 361. GEQ-Line 20 Amp 1 in. ...
- Top Rated. GEQ-Line 15 Amp Single-Pole Dual Function Arc Fault/GFCI Breaker.
What kind of circuit breakers does General Electric make?
GE’s Q-Line residential circuit breaker is available in six model types ranging from one to one-half inch sizes, each with distinct amp ratings and pole designations. The THQP model is one-half inch in size and available for one or two pole designations, with a current rating of 15 to 50 amps. Circuit breakers with a size of one inch and 15 to 125 ...
What are the different types of circuit breakers?
17 rows · Larger motors and air conditioners, clothes dryers and hot water heaters will typically require a 30 ...
What are the different sizes of Gege Q-line circuit breakers?
21/03/2017 · This type’s primary use is for lighter commercial structures with low surge currents, such as light fixtures. Type C MCBs trip between 5 and 10 times per full current load. Type C is used for heavier commercial and general industrial applications that have a higher short-circuit currents. Lastly, Type D circuit breakers trip between 10 and 20 times.
What breakers are compatible with GE panel?
27/03/2020 · There are two types of standard breakers: single-pole and double-pole. Single- pole breakers are rated for 120 volts and 15 or 20 amps . Double - pole breakers , on the other hand, are typically rated for 20 to 60 amps and supply 240-volt power to large appliances, like electric dryers and ranges.
How do I identify a GE breaker?
0:091:53How to Identify GE Power Break Circuit Breakers - YouTubeYouTubeStart of suggested clipEnd of suggested clipThey're typically located on each side of the breaker. You can also identify by the chain-drivenMoreThey're typically located on each side of the breaker. You can also identify by the chain-driven racking mechanism. This is an older style draw-out referred to as the houston.
What breaker is compatible with GE?
Siemens breakers can be used in GE breaker boxes, and they are generally known to be compatible. Match the size and voltage requirements when using Siemens breakers, as using the wrong breakers can have dangerous results.
What are the four types of circuit breakers?
There are four basic circuit breakers that are standard in most modern homes: single-pole, double-pole, GFCIs, and AFCIs. And don't worry, if you are unfamiliar with the different types of circuit breakers, we're here to help you understand the difference and explain their importance.02-Feb-2021
What is the difference between Type C and Type D circuit breakers?
Type C devices are designed to trip at 5-10 times In (50-100A for a 10A device). Type D devices are designed to trip at 10-20 times In (100-200A for a 10A device).
Can I use an Eaton breaker in a GE panel?
TLDR: They're all wrong. Swap with a GE or classified breaker (e.g. Eaton CL not BR).18-Nov-2019
Will a Square D breaker fit in an Eaton panel?
Designed to fit virtually any panel Eaton's UL classified breakers are designed and tested to be both mechanically and electrically interchangeable with circuit breakers manufactured by General Electric, Thomas & Betts, ITE/Siemens, Murray, Crouse-Hinds, and Square D. Video Player is loading.
What does QP mean on a circuit breaker?
The type QP circuit breakers are intended for protection of residential or commercial electrical wiring. There are 1 or 2 poles for Circuit Breaker QP types. The range of Amps is from 15 to 125. There are two types of voltages, 120 and 120.
What are the 2 types of circuit breakers?
Standard circuit breakers come in two varieties: single-pole breakers and double-pole breakers. These are simpler breakers that monitor the cadence of electricity as it circulates an indoor space. It keeps track of electricity in electrical wiring systems, appliances and outlets.15-Jul-2019
What is a Type C circuit breaker?
Type C circuit breakers are used for more powerful electrical devices where any surges are likely to be higher – typically commercial and industrial environments. They are designed to trip at currents between five and ten times their rated load. Good examples include smaller electric motors and fluorescent lighting.
Can you use Type C MCB in domestic?
As others point out, the use of type C MCBs can be desirable on domestic lighting circuits in order to reduce nuisance tripping when lamps fail.28-Mar-2009
What is the difference between B curve and C curve?
B curve breakers: Trip between 3-5 times rated current in a short circuit situation. ... C curve breakers: Trip between 6-10 times rated current in a short circuit situation. C curve MCBs should be applied where the loads have a small amount of in-rush current on start-up.
Should I use MCB or RCBO?
MCB can provide protection against overcurrent and short circuit only while RCBO can provide protection against overcurrent and earth leakage. MCb can not protect against earth faults while in RCBO can protect against earth fault, electric shocks that MCB may not do.
What is a THQP breaker?
When size and money are driving considerations, THQP breakers are the smart choice. THQP (1/2" Breaker) THQL (1" Breaker) 2. 1-pole or 2-pole? Most circuits require only a 1-pole circuit breaker. That includes lighting, standard outlets and most other applications.
How many amps does a circuit breaker need?
Generally, this means that lighting and outlets will call for 15 or 20 amp breakers. Larger motors and air conditioners, clothes dryers and hot water heaters will typically require ...
What is a circuit breaker?
A circuit breaker protects the circuit (or wire) between the breaker and the electrical load. It uses a magnetic element (instantaneous unit) to protect against short circuits and a thermal element (bimetal strip) to protect against overloads. It also provides a way to turn a circuit off.
Can I use Siemens breaker boxes with GE?
Siemens breakers can be used in GE breaker boxes, and they are generally known to be compatible. Match the size and voltage requirements when using Siemens breakers, as using the wrong breakers can have dangerous results. If the wrong breaker is used it could fail to break (shut off power) during a surge. Similarly one may ask, are GE and Eaton ...
Is there such a thing as an interchangeable circuit breaker?
There is no such thing as an interchangeable circuit breaker. There are however CLASSIFIED breakers that are suitable only for replacement of certain breakers in certain panelboards.
Is a breaker interchangeable?
Brand: Always install the correct brand of breakers in your breaker panel. While some breakers are interchangeable, many are not, even if they look the same. Similar Asks.
Why use thermal trip unit in circuit breaker?
One of the benefits of having a thermal trip unit in the circuit breaker is that it allows for quick but non-harmful overloads. These are commonly produced by the bursts of current required to start up engines, electrical saws and the like. These spikes of current are not so large as to cause damage.
What is a circuit breaker?
Guide to Types of Circuit Breakers. A circuit breaker is an automatic electrical shutoff switch that protects circuits from overcurrent. Overcurrent, or excess amperage, can come from an overload of the circuit, short-circuiting, an arc fault or a ground fault. Circuit breakers make use of the increased heat or magnetic field from ...
How many volts does a vacuum circuit breaker handle?
Indoor applications have long used air for breaking the arc, but they’re increasingly converting to vacuum breakers below about 40,500 volts.
Can MCCBs handle more voltage?
MCCBs can handle more voltage , and because of the different requirements set on them, they come in different casing and with different components. Low-voltage circuit breakers are designed to be easily serviced. They’re often easily disassembled for repairs without a user having to take the switchgear apart.
What is actuator lever?
Their parts may include the following: Lever: The actuator lever is the part that is visible to the user. When the circuit is tripped, this lever flips and must be manually flipped back to close the circuit again. Note that most levers can still trip even when locked in position — an important safety feature.
How does a magnetic circuit breaker work?
Magnetic circuit breakers exploit this effect by attaching the solenoid to a latch, which keeps the contacts of the circuit pressed together.
Can a circuit breaker be used on direct current?
Some assemblies are automatic, allowing an operator to open and close them remotely. These circuit breakers can also be used on direct current applications. Because direct current’s internal electrical arc does not stop and start as with alternating current, a different type of breaker must be used within the unit.
What are the different types of circuit breakers?
Broadly speaking, there are three major types of circuit breakers: standard, ground fault circuit interrupters (GFCIs), and arc fault circuit interrupters (AFCIs). Let’s take a closer look at these three. Standard Circuit Breakers. When you imagine a simple breaker that trips when a circuit overloads, you’re probably thinking ...
Is buying a circuit breaker trivial?
Buying circuit breakers is no trivial task, so how do you ensure you’re making the correct decision? As it turns out, picking the right one isn’t too complicated, and it all starts with learning how to identify different types of circuit breakers.
What is a double pole breaker?
Double-pole breakers are more common for large residential appliances or commercial facilities, and take up two slots. In wet areas such as kitchens, bathrooms, or in damp industrial conditions, you will often encounter outlets with two buttons on them (“test” and “reset”) — these are protected by a GFCI breaker.
THQP150 - GE 50 Amp 1 Pole 240 Volt Plug-In Molded Case Circuit Breaker
THQP150 - GE 50 Amp 1 Pole 240 Volt Plug-In Molded Case Circuit Breaker General Electric THQP series single pole 50 ampere bolt-on molded case circ...
THQP135 - GE 35 Amp 1 Pole 240 Volt Plug-In Molded Case Circuit Breaker
THQP135 - GE 35 Amp 1 Pole 240 Volt Plug-In Molded Case Circuit Breaker General Electric THQP series single pole 35 ampere bolt-on molded case circ...
THQP145 - GE 45 Amp 1 Pole 240 Volt Plug-In Molded Case Circuit Breaker
THQP145 - GE 45 Amp 1 Pole 240 Volt Plug-In Molded Case Circuit Breaker General Electric THQP series single pole 45 ampere bolt-on molded case circ...
THQL1160 - GE 60 Amp 1 Pole 120 Volt Plug-In Molded Case Circuit Breaker
THQL1160 - GE 60 Amp 1 Pole 120 Volt Plug-In Molded Case Circuit Breaker General Electric Q-Line THQL series single pole 60 ampere plug-on molded c...
THQL1150 - GE 50 Amp 1 Pole 120 Volt Plug-In Molded Case Circuit Breaker
THQL1150 - GE 50 Amp 1 Pole 120 Volt Plug-In Molded Case Circuit Breaker General Electric Q-Line THQL series single pole 50 ampere plug-on molded c...
THQL1135 - GE 35 Amp 1 Pole 120 Volt Plug-In Molded Case Circuit Breaker
THQL1135 - GE 35 Amp 1 Pole 120 Volt Plug-In Molded Case Circuit Breaker General Electric Q-Line THQL series single pole 35 ampere plug-on molded c...
THQL1145 - GE 45 Amp 1 Pole 120 Volt Plug-In Molded Case Circuit Breaker
THQL1145 - GE 45 Amp 1 Pole 120 Volt Plug-In Molded Case Circuit Breaker General Electric Q-Line THQL series single pole 45 ampere plug-on molded c...
Molded Case Circuit Breakers
ABB‘s SACE® FORMULA molded case circuit breaker line offers simplicity and quality in some of the smallest dimensions available.
Low Voltage Power Circuit Breakers
Air circuit breakers up to 6300A. From circuit breaker to power manager
Miniature Circuit Breakers & Supplementary Protectors
UL1077 MCBs feature two tripping mechanisms, the delayed thermal tripping mechanism and the magnetic tripping mechanism, to ensure electrical safety in multiple applications.
Enclosed Circuit Breakers
ABB offers a variety of NEMA enclosure types designed to protect against a variety of environmental conditions in non-hazardous locations.
AC Circuit Breakers for Railway
Single-pole and double pole outdoor vacuum load break switch and vacuum circuit-breaker with magnetic actuator for railway applications.
Insulated Case Circuit Breakers
800 to 4000A. This breaker provides reliable, flexible and easy-to use circuit protection. Utilizes the EntelliGuard* TU trip unit.
Residential Circuit Breakers
100 to 225A. THQMV Main breakers are configured to allow top or bottom feed without modification and can be added to PowerMark Gold convertible (TLM) load centers.

Low-Voltage Circuit Breakers
- These are one of the most common types of circuit breaker on the market and can be found in homes, businesses and industries. They include the following models: 1. Miniature Circuit Breakers (MCB): Miniature Circuit Breakers do not handle currents higher than 100 amps, which makes them suitable for many home and business applications. Once installed, they’re simple t…
Medium-Voltage Circuit Breakers
- These circuit breakers handle voltages between 1,000 and 72,000 volts and are installed for both indoor and outdoor use. Indoor applications have long used air for breaking the arc, but they’re increasingly converting to vacuum breakers below about 40,500 volts. Current transformers detect the current moving through the circuits and trip circuits using an electrically controlled sw…
High-Voltage Circuit Breakers
- When voltages rise above a certain point, the International Electrotechnical Commissionranks it as “high voltage.” These breakers use solenoids operated by protective relays and current transformers. They often feature complicated safety nets to prevent overcurrent, which can come in several forms. These breakers use a number of different forms to break the arc: bulk oil, mini…
Magnetic Circuit Breakers
- This type of circuit breaker takes the form of a solenoid, or electromagnetic coil. As current passes through a solenoid, it undergoes a magnetic force that is angled perpendicularly through its center. This force increases with the amount of current. Magnetic circuit breakers exploit this effect by attaching the solenoid to a latch, which keeps the contacts of the circuit pressed toget…
Thermal-Magnetic Circuit Breakers
- Whereas a magnetic circuit breaker relies on magnetism alone to break the circuit, a thermal-magnetic circuit breaker uses both heat and magnetism to detect overcurrent. This circuit breaker is the most common type found in distribution boards, which are the panels of breakers controlling different circuits within a house or building. A magnetic circuit breaker uses a solenoi…
Magnetic-Hydraulic Circuit Breakers
- This type of circuit breaker uses the magnetic solenoid as its core operating part. The solenoid responds to current in the same way as a standard magnetic circuit breaker and is held in place by a spring that will not compress until a threshold limit is reached. However, this time, the movement of the solenoid is dampened by a viscous hydraulic fluid. When the circuit reaches it…
Other Types of Breakers
- Other types of circuit breakers exist for different applications. Here are a few that do not fit into the previous categories: 1. Residual current device: Also known as a ground-fault circuit interrupter, this device detects a difference in current between the hot wire and neutral wire. Normally, the same amount of current should be flowing through both, so if it isn’t, that could be …