Receiving Helpdesk

does ditra heat need a dedicated circuit

by Hattie Fritsch Published 3 years ago Updated 3 years ago

A dedicated circuit is required for DITRA-HEAT. If you’re not comfortable doing this yourself call in a licensed electrician. Also, we used metal conduit per local code. Although a GFCI is required for DITRA-HEAT, the DITRA-HEAT-E-RT/-RSD/-R thermostats include a GFCI.

Full Answer

Can a Ditra thermostat be used with a Ditra-heat-E-RR?

• Multiple DITRA-HEAT-E-HK heating cables over 15 amps cannot be connected to a single DITRA-HEAT-E thermostat. Additional DITRA-HEAT-E thermostats must be used, or a DITRAHEAT-E thermostat may be combined with the DITRA-HEAT-E-RR power modules.

Do I need a dedicated circuit for a Ditra-heat?

A dedicated circuit is required for DITRA-HEAT. If you’re not comfortable doing this yourself call in a licensed electrician. Also, we used metal conduit per local code. Although a GFCI is required for DITRA-HEAT, the DITRA-HEAT-E-RT/-RSD/-R thermostats include a GFCI.

How do you use a Ditra heat membrane?

Keep the DITRA-HEAT membrane a minimum of 1/8 to 1/4 inch from walls. Cut membranes or mats using a utility knife. If you use the roll it’s a good idea to counter roll it. Counter rolling prevents the membrane from pulling up from the thin-set.

Are Ditra heat treated tiles waterproof?

DITRA-HEAT and DITRA-HEAT-TB provide reliable waterproofing in interior applications. The products have been found to meet or exceed the requirements of the American National Standard Specifications for Load Bearing, Bonded, Waterproof Membranes for Thin-set Ceramic Tile and Stone Installation A118.10.

Does in floor heat need a dedicated circuit?

If you're installing radiant floor heat in an existing room, you'll need a dedicated 15- to 20-amp GFCI-protected circuit to power the system, and an excuse to lay a new tile floor. If you're remodeling, it's a good time to satisfy both requirements.

Can I use a 15 amp breaker for DITRA-HEAT?

Multiple DITRA-HEAT-E-HK heating cables over 15 amps cannot be connected to a single DITRA-HEAT-E thermostat.

How many amps does a Schluter heated floor use?

Technical DetailsManufacturer‎Schluter SystemsPower Source‎Corded electricVoltage‎240 VoltsWattage‎2850 wattsAmperage Capacity‎11.9 Amps4 more rows

Does DITRA-HEAT need a GFCI breaker?

Our thermostats have a built-in GFCI, so a GFCI is not required at the breaker.

How do you wire Ditra heat?

2:256:11Ditra-Heat Installation (Part 2: Cable Installation) - YouTubeYouTubeStart of suggested clipEnd of suggested clipSo running the cable is fairly easy and straightforward as long as you maintain that three studMoreSo running the cable is fairly easy and straightforward as long as you maintain that three stud pattern you can do in alternating 3/2 stud spacing per the Schluter dieter heat directions.

How much power does a heated bathroom floor use?

A typical electric floor heating element produces 15 watts per square foot. When installed in a small 35 square foot bathroom running a total of 8 hours a day, the system would only use 4.2 kWh per day. That's 128.1 kWh per month. The national average kWh rate is $0.12.

What is the difference between Ditra heat and Ditra Heat duo?

0:272:42How to choose between DITRA-HEAT & DITRA-HEAT-DUO - YouTubeYouTubeStart of suggested clipEnd of suggested clipYou would use our ditra heat duo product ok very good the difference between the two is just theMoreYou would use our ditra heat duo product ok very good the difference between the two is just the backing of the material. And so if you look at the regular Detra heat membrane.

Are 240V heater more efficient than 120V?

240V is most common for electrical appliances which require more power, such as a dryer, electric stove, or hot tub. There is no difference in efficiency in our heaters between 120V and 240V (or any other voltage). The reason why 240V is advantageous for appliances and heaters in a home has to do with amperage.

Is it less expensive to operate the electric heating unit on 240V or 120V?

The simple answer is that they are almost the same price to operate.

Does floor heat have to be GFCI protected?

GFCI protection is NOT required for floor heating cables in a kitchen.

Do heated floors require GFCI?

If you have radiant floor heating and an imbalance within the electrical currents occurs, the GFCI in the radiant heat thermostat will automatically and instantly disconnect the electrical lines from the radiant heating system. The WarmlyYours thermostats are GFCI protected and a GFCI breaker is not necessary.

How long does DITRA-HEAT take to warm up?

How long do I have to wait after the installing Schluter®-DITRA-HEAT to start using the system? Schluter®-Systems recommends waiting 7 days after grouting before consistent use of the DITRA-HEAT system. Turning the system on briefly (e.g., 5 or 10 minutes) immediately after installation to check functionality is safe.

Does a KERDI band need to be sealed?

all seams in DITRA-HEAT and DITRA-HEAT-TB matting and floor/wall transitions must be sealed with KERDI-BAND using unmodified thin-set mortar. Note: KERDI-BAND must lap DITRA-HEAT at seams and at floor/wall transitions by a minimum of 2" (50 mm) in order to maintain waterproof integrity

Can you put furniture over a floor temperature sensor?

Do not place furniture or mats over the floor temperature sensor. They can act as insulation and raise the floor temperature reading at the thermostat. This may cause the heating to turn off before the remainder of the floor reaches the desired temperature.

How to remove kerdi?

1/ to peel off the kerdi, refill all the voids with unmodified thinset then glue a new kerdi on it with liquid form thinset. 2/ peel off the kerdi, refill all the voids with unmodified thinset, let it dry, and aftewards paint liquid membrane on it. 3/ do nothing, let it so, it will be ok.

Can you put vinyl planks over ditra heat?

Short answer, yes you can install other materials over Ditra Heat Duo, they sent me a bulletin explaining what to do. In my case, I’m installing vinyl plank (floating) over the Ditra. The bulletin says use a “cementious self-levelling underlayment” for which I used Levelquik RS.

Can you use Ditra heat TB over concrete?

An additional benefit of prefilling Ditra mats is being able to snap chalk lines and actually being able to read them. Ditra Heat TB has additional insulation for going over concrete floors.

Do radiant heat systems require a dedicated circuit?

Some of the under floor radiant heat systems don't require a dedicated circuit. eg. 'sun touch'. Under floor heating is much different than electric strip/coil heaters. What I would do is figure out the square footage of radiant heat (it doesn't have to go next to the walls) and calculate the wattage.

Does Nuheat require a dedicated branch circuit?

The Nuheat company does not require a dedicated branch circuit. In reference to the NEC: The maximum load for utilization equipment fastened in place (floor mat) on the same circuit with luminares or cord and plug equipment is 50% of the branch circuit rating.