You need the neutral to make the light work but you can take a spur from the socket underneath the desk for a light, you could place a FCU next to socket underneath desk then run cable to light switch and then on to light fitting.. you cannot run spur to spur with sockets incase of over load of cable but a light is totally different just fuse the FCU at 3 amps..
Do I need a fused spur for a light socket?
If taking the new light from the lighting circuit,which is the preffered option, there is no need for a fused spur/fcu. Click to see full answer. Simply so, can I spur a socket from a light?
Do you turn off the outside socket when plugging in?
you dont need to turn of the outside socket unless you want too incase someone tries to pinch your power you could put a FCU in front of the socket rated at 13 amp dont forget the external socket has to be IP rated (please dont think im calling you thick im not) Click to expand...
Can you run a spur cable to an existing socket?
The easiest way of connecting into a ring circuit is to run a spurcable from the terminals of an existing socket– but you can't connect it to any socket. The IEE Wiring Regulations are very specific about this. You mustn't run a spurfrom a socketthat's already on a spur, or that already supplies a spur. Can I use 1.5 mm cable for sockets?
How many spurs can you take off a socket?
How many Spurs can you take off one socket? A spur can be connected to an existing socket, on either a ring main or a radial circuit, providing that socket does not already have a spur. That is only one spur per socket is allowed and the number of spurs must not exceed the number of sockets.
Is it OK to spur off a socket?
The easiest way of connecting into a ring circuit is to run a spur cable from the terminals of an existing socket – but you can't connect it to any socket. The IEE Wiring Regulations are very specific about this. You mustn't run a spur from a socket that's already on a spur, or that already supplies a spur.
Can I wire a light to a plug?
Yes, you can. You must make sure at the lamp end that the flex is securely gripped by a suitable cable gland or other strain relief to prevent the cable being tugged out and exposing live wires.
Can I run a spur from a light switch?
Unless there is a neutral at the light switch, you'd better run the spur from the nearest light fitting.
Can you Spur twice off one socket?
A spur can be connected to an existing socket, on either a ring main or a radial circuit, providing that socket does not already have a spur. That is only one spur per socket is allowed and the number of spurs must not exceed the number of sockets.
Can I wire a ceiling light to a plug UK?
Yes, you can get a plug and attach the two wires from the cord to the non-earth (ground) pins of the plug.
How do you run a light switch from a socket?
4:005:19Light spur from socket Spur for lighting off ring main wiring connectionYouTubeStart of suggested clipEnd of suggested clipOne is coming from the FCO. And another one is going up to the light fitting. So as you see both noMoreOne is coming from the FCO. And another one is going up to the light fitting. So as you see both no trans from both these cables connected together by go connector.
Are lights and sockets on same circuit?
Technically, you can wire a socket onto a light circuit, but it is not recommended. There can be problems with overloading the circuit. If you add a socket to a lighting circuit, do it in parallel. Otherwise, the light switch will control the circuit.
Can you run a fused spur off a light switch?
You can install either a switched fused spur, which will also function as the on-off button or an unswitched fused spur alongside a conventional light switch.
How do you run a light from another light?
1:334:34Basics: Adding a Light to An Existing Circuit - YouTubeYouTubeStart of suggested clipEnd of suggested clipYou'll want to just cut off the copper and start again it's always best practice to do thatMoreYou'll want to just cut off the copper and start again it's always best practice to do that sometimes the cable is new enough that you can manipulate the cores again without them breaking on you.
How do you run a spur from an existing socket?
6:3416:51How to Add a Socket to Ring or Radial Circuits | Spur Off Wiring ExplainedYouTubeStart of suggested clipEnd of suggested clipOr we can spur. Off an existing socket. Like in this picture here if you're like me and you'reMoreOr we can spur. Off an existing socket. Like in this picture here if you're like me and you're following this video and you want to do this with a junction. Box because in my scenario.
How many Spurs can you take from one socket?
one fused spurOnly one fused spur may be taken from any socket on a ring. From that fused spur you can have as many electrical outlets as you like, as they are then protected by the fuse.
Can I run a fused spur from a socket?
If the 13 amp fused spur is on the ring circuit and you want to add a socket to the load side of the fused spur yes that is fine as that individual socket will be protected by the 13a fuse in the spur. If unsure please call a qualified electrician to carry out your works to be on the safe side.